Related Experiment Video
Updated: May 2, 2026

Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies
Published on: April 11, 2016
Internal validation of the GlobalFiler™ Express PCR Amplification Kit for the direct amplification of reference DNA
Shahida Flores1, Jie Sun1, Jonathan King1
1Institute of Applied Genetics, Department of Forensics and Investigative Genetics, University of North Texas Health Science Center, Fort Worth, TX 76107, USA.
Abstract:
The GlobalFiler™ Express PCR Amplification Kit uses 6-dye fluorescent chemistry to enable multiplexing of 21 autosomal STRs, 1 Y-STR, 1 Y-indel and the sex-determining marker amelogenin. The kit is specifically designed for processing reference DNA samples in a high throughput manner. Validation studies were conducted to assess the performance and define the limitations of this direct amplification kit for typing blood and buccal reference DNA samples on various punchable collection media. Studies included thermal cycling sensitivity, reproducibility, precision, sensitivity of detection, minimum detection threshold, system contamination, stochastic threshold and concordance. Results showed that optimal amplification and injection parameters for a 1.2mm punch from blood and buccal samples were 27 and 28 cycles, respectively, combined with a 12s injection on an ABI 3500xL Genetic Analyzer. Minimum detection thresholds were set at 100 and 120RFUs for 27 and 28 cycles, respectively, and it was suggested that data from positive amplification controls provided a better threshold representation. Stochastic thresholds were set at 250 and 400RFUs for 27 and 28 cycles, respectively, as stochastic effects increased with cycle number. The minimum amount of input DNA resulting in a full profile was 0.5ng, however, the optimum range determined was 2.5-10ng. Profile quality from the GlobalFiler™ Express Kit and the previously validated AmpFlSTR(®) Identifiler(®) Direct Kit was comparable. The validation data support that reliable DNA typing results from reference DNA samples can be obtained using the GlobalFiler™ Express PCR Amplification Kit.
More Related Videos
08:23Single Droplet Digital Polymerase Chain Reaction for Comprehensive and Simultaneous Detection of Mutations in Hotspot Regions
Published on: September 25, 2018
12:14A Duplex Digital PCR Assay for Simultaneous Quantification of the Enterococcus spp. and the Human Fecal-associated HF183 Marker in Waters
Published on: March 9, 2016
Related Concept Videos
DNA Isolation
Real Time RT-PCR
The real-time quantification of the number of amplified products is...