Low StO2 measurements in surgical intensive care unit patients is associated with poor outcomes
Uroghupatei P Iyegha1, Tyler Conway, Kristin Pokorney
1From the Department of Surgery (U.P.I., K.P., K.E.M., G.J.B.), and School of Medicine (T.C.), University of Minnesota, Minneapolis; and Technomics Research (T.N.), LLC, Medina, Minnesota.
Background:
Near-infrared spectroscopy-derived tissue hemoglobin saturation (StO2) is a noninvasive measurement that reflects changes in microcirculatory tissue perfusion. Previous studies in trauma patients have shown a correlation between low StO2 levels and mortality, organ failure, and severity of injury. The goals of this study were to identify the incidence of low StO2 in the critically ill patient population of a surgical intensive care unit (SICU) and evaluate the relationship of low StO2 and clinical outcomes.
Methods:
We conducted a prospective cohort study at the University of Minnesota Medical Center. After institutional review board approval, 620 patients admitted to the SICU between July 2010 and July 2011 were screened for enrollment. Patients with an expected ICU length of stay of less than 24 hours were excluded. In the 490 patients who met inclusion criteria, StO2 measurements were obtained from the thenar eminence one to three times daily for the length of the ICU stay, up to 14 days. Outcome data included 28-day hospital mortality; ICU readmission; ventilator-free, ICU-free, and hospital-free days; and the need for lifesaving interventions.
Results:
The overall incidence of low StO2 (<70%) was 11% of the patients per day. Patients with at least 1 day in the SICU with an StO2 measurement of less than 70% had higher rates of ICU readmission and fewer ventilator-free, ICU-free, and hospital-free days compared with those who did not. Mortality (28-day in-hospital) trended higher for these patients but was not statistically significant. An increase in the number of days with StO2 less than 70% was also associated with fewer ventilator-free, ICU-free, and hospital-free days.
Conclusion:
Low StO2 (<70%) is common and associated with poor outcomes in SICU patients. Near-infrared spectroscopy represents a potentially useful, noninvasive adjunct to monitoring of critically ill patients.
Level Of Evidence:
Prognostic study, level II.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Atelectasis II: Pathophysiology
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...