Abstract:
The value of (99m)Tc-labeled white blood cell scintigraphy for endovascular prosthetic infections is well known. In the unique case reported here, infection of the native aorta was detected in addition to an infected vascular prosthesis. The case demonstrates that (99m)Tc-labeled white blood cell scintigraphy can identify not only the more usual prosthetic stent/graft infection but also infection of the native aorta. When scrutinizing studies for infection of prosthetic material, readers should also carefully examine the native aorta.