Related Experiment Video
Updated: May 2, 2026

Rapid and Low-cost Prototyping of Medical Devices Using 3D Printed Molds for Liquid Injection Molding
Published on: June 27, 2014
Comparing suppository mold variability which can lead to dosage errors for suppositories prepared with the same or
Kenneth S Alexander1, Gabriella Baki2, Christine Hart2
1University of Toledo, College of Pharmacy and Pharmaceutical Sciences, Toledo, OH 43614, USA. kenneth.alexander@utoledo.edu
Abstract:
Suppository molds must be properly calibrated to ensure accurate dosing. There are often slight differences between molds and even in the cavities within a mold. A method is presented for the calibration of standard aluminum 6-, 12-, 50-, or 100-well suppository molds. Ten different molds were tested using water for volume calibration, and cocoa butter for standardization involving establishing the density factor. This method is shown to be straightforward and appropriate for calibrating suppository molds.
Related Concept Videos
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Dosage Regimen: Individualization
Pharmaceutical Alternatives: Excipients and Impurities-Related Therapeutic Nonequivalence
Drug Dissolution: Requirements and Profile Comparison
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence