Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

The Uncertainty Principle04:08

The Uncertainty Principle

25.6K
Werner Heisenberg considered the limits of how accurately one can measure properties of an electron or other microscopic particles. He determined that there is a fundamental limit to how accurately one can measure both a particle’s position and its momentum simultaneously. The more accurate the measurement of the momentum of a particle is known, the less accurate the position at that time is known and vice versa. This is what is now called the Heisenberg uncertainty principle. He...
25.6K
π Electron Effects on Chemical Shift: Overview01:27

π Electron Effects on Chemical Shift: Overview

1.5K
An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0,...
1.5K
Motion Of A Charged Particle In A Magnetic Field01:22

Motion Of A Charged Particle In A Magnetic Field

6.5K
A charged particle experiences a force when moving through a magnetic field. Consider the field to be uniform and the charged particle to move perpendicular to it. If the field is in a vacuum, the magnetic field is the dominant factor determining the motion. Since the magnetic force is perpendicular to the direction of motion, a charged particle follows a curved path. The particle continues to follow this curved path until it forms a complete circle. Another way to look at this is that the...
6.5K
Electromagnetic Fields01:30

Electromagnetic Fields

1.7K
Electric fields generated by static charges, often referred to as electrostatic fields, are characteristically different from electric fields created by time-varying magnetic fields. While the former is a conservative field, implying that no net work is done on a test charge if it goes around in a complete loop in the field, the latter is, by definition, not a conservative field; net work is done, and it is proportional to the rate of change of magnetic flux.
However, the observation of...
1.7K
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

785
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
785
The de Broglie Wavelength02:32

The de Broglie Wavelength

25.7K
In the macroscopic world, objects that are large enough to be seen by the naked eye follow the rules of classical physics. A billiard ball moving on a table will behave like a particle; it will continue traveling in a straight line unless it collides with another ball, or it is acted on by some other force, such as friction. The ball has a well-defined position and velocity or well-defined momentum, p = mv, which is defined by mass m and velocity v at any given moment. This is the typical...
25.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Treatment of Base of Condyle Fracture Using Minimal Access Surgery: Infinitesimal Peri-Angular Pterygomasseteric Transsectioning Approach (IPPTA): A Case Report.

Mymensingh medical journal : MMJ·2026
Same author

[Three cases of laryngeal myxoma].

Zhonghua er bi yan hou tou jing wai ke za zhi = Chinese journal of otorhinolaryngology head and neck surgery·2026
Same author

Digital quantum magnetism on a trapped-ion quantum computer.

Nature·2026
Same author

[The interaction of workplace noise, body mass index and systemic inflammatory response on hypertension].

Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases·2025
Same author

Phylogeny of multiple genomic regions of infectious laryngotracheitis virus in Turkish poultry flocks.

Poultry science·2025
Same author

Deciphering genomic basis of unique adaptation of Ladakhi cattle to Trans-Himalayan high-altitude region of Leh-Ladakh in India.

Gene·2025

Related Experiment Video

Updated: May 2, 2026

An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers
09:49

An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers

Published on: October 23, 2018

15.9K

Electron gun jitter effects on beam bunching.

M S Liu1, M Iqbal1

  • 1Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.

The Review of Scientific Instruments
|March 6, 2014
PubMed
Summary

Beijing Electron Positron Collider II (BEPCII) linac operation is sensitive to beam bunching. Gun timing jitter significantly impacts beam energy more than voltage jitter, affecting performance and injection rates.

Area of Science:

  • Particle accelerators
  • Beam physics
  • High-energy physics instrumentation

Background:

  • The Beijing Electron Positron Collider II (BEPCII) linac is crucial for particle physics experiments.
  • Stable beam bunching is essential for efficient collider operation and data acquisition.
  • Various factors, including electronic jitter, can disrupt the beam bunching process.

Purpose of the Study:

  • To quantitatively measure and analyze the impact of gun timing jitter and gun high voltage jitter on the BEPCII linac.
  • To determine the relative effects of these jitters on beam energy and overall performance.
  • To identify critical jitter thresholds that degrade beam quality and injection rates.

Main Methods:

  • Utilized precise measurement techniques to quantify gun timing jitter and gun high voltage jitter.

More Related Videos

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
08:31

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

Published on: June 27, 2022

2.1K
20 mJ, 1 ps Yb:YAG Thin-disk Regenerative Amplifier
10:17

20 mJ, 1 ps Yb:YAG Thin-disk Regenerative Amplifier

Published on: July 12, 2017

12.4K

Related Experiment Videos

Last Updated: May 2, 2026

An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers
09:49

An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers

Published on: October 23, 2018

15.9K
Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
08:31

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

Published on: June 27, 2022

2.1K
20 mJ, 1 ps Yb:YAG Thin-disk Regenerative Amplifier
10:17

20 mJ, 1 ps Yb:YAG Thin-disk Regenerative Amplifier

Published on: July 12, 2017

12.4K
  • Measured beam energy at the exit of the standard acceleration section.
  • Performed analytical comparisons to assess the differential impact of timing versus voltage jitter.
  • Main Results:

    • Measured gun high voltage jitter up to 80 mV and timing jitter exceeding 200 ps.
    • Analysis revealed that gun timing jitter has a more severe effect on beam energy compared to gun high voltage jitter.
    • A timing jitter threshold of 100 ps was identified as critical for performance degradation.

    Conclusions:

    • Gun timing jitter is a primary concern for maintaining optimal BEPCII linac performance.
    • Exceeding the 100 ps timing jitter threshold significantly deteriorates beam performance and storage ring injection rates.
    • Mitigating gun timing jitter is essential for the routine operation and efficiency of the BEPCII collider.