Related Experiment Video
Updated: May 2, 2026

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells
Published on: August 20, 2019
Transverse distribution of beam current oscillations of a 14 GHz electron cyclotron resonance ion source
O Tarvainen1, V Toivanen1, J Komppula1
1University of Jyvaskyla, Department of Physics, 40500 Jyvaskyla, Finland.
Abstract:
The temporal stability of oxygen ion beams has been studied with the 14 GHz A-ECR at JYFL (University of Jyvaskyla, Department of Physics). A sector Faraday cup was employed to measure the distribution of the beam current oscillations across the beam profile. The spatial and temporal characteristics of two different oscillation "modes" often observed with the JYFL 14 GHz ECRIS are discussed. It was observed that the low frequency oscillations below 200 Hz are distributed almost uniformly. In the high frequency oscillation "mode," with frequencies >300 Hz at the core of the beam, carrying most of the current, oscillates with smaller amplitude than the peripheral parts of the beam. The results help to explain differences observed between the two oscillation modes in terms of the transport efficiency through the JYFL K-130 cyclotron. The dependence of the oscillation pattern on ion source parameters is a strong indication that the mechanisms driving the fluctuations are plasma effects.
Related Concept Videos
Continuous Charge Distributions
The electric charge can also be subjected to an analogical...
Oscillations In An LC Circuit
Mass Analyzers: Common Types
Generating Electromagnetic Radiations
Atomic Nuclei: Nuclear Relaxation Processes
Atomic Nuclei: Larmor Precession Frequency