Related Experiment Video
Updated: May 2, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Quality and precision of parametric images created from PET sinogram data by direct reconstruction: proof of concept
Abstract:
We have previously implemented the direct reconstruction of dense kinetic model parameter images ("parametric images") from sinogram data, and compared it to conventional image domain kinetic parameter estimation methods . Although it has been shown that the direct reconstruction algorithm estimates the kinetic model parameters with lower root mean squared error than the conventional image domain techniques, some theoretical obstacles remain. These obstacles include the difficulty of evaluating the accuracy and precision of the estimated parameters. In image domain techniques, the reconstructed time activity curve (TAC) and the model predicted TAC are compared, and the goodness-of-fit is evaluated as a measure of the accuracy and precision of the estimated parameters. This approach cannot be applied to the direct reconstruction technique as there are no reconstructed TACs. In this paper, we propose ways of evaluating the precision and goodness-of-fit of the kinetic model parameters estimated by the direct reconstruction algorithm. Specifically, precision of the estimates requires the calculation of variance images for each parameter, and goodness-of-fit is addressed by reconstructing the difference between the measured and the fitted sinograms. We demonstrate that backprojecting the difference from sinogram space to image space creates error images that can be examined for goodness-of-fit and model selection purposes. The presence of nonrandom structures in the error images may indicate an inadequacy of the kinetic model that has been incorporated into the direct reconstruction algorithm. We introduce three types of goodness-of-fit images. We propose and demonstrate a number-of-runs image as a means of quantifying the adequacy or deficiency of the model. We further propose and demonstrate images of the F statistic and the change in the Akaike Information Criterion as devices for identifying the statistical advantage of one model over another at each voxel. As direct reconstruction to parametric images proliferates, it will be essential for imagers to adopt methods such as those proposed herein to assess the accuracy and precision of their parametric images.
More Related Videos
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018