Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

1.5K
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.5K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

2.3K
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
2.3K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

2.2K
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
2.2K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

2.3K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.3K
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

3.0K
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
3.0K
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

2.7K
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
2.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Nitric oxide-releasing balloon inflation fluid for Foley catheters to prevent catheter-associated urinary tract infections.

Microbiology spectrum·2026
Same author

Nitric Oxide-Releasing Surfaces Reduce Thrombosis in Venovenous Extracorporeal Life Support: A 5 day Long Ovine Study.

ASAIO journal (American Society for Artificial Internal Organs : 1992)·2026
Same author

Photolysis of solid-state S-nitrosoglutathione: Mechanism and kinetics of nitric oxide release.

Nitric oxide : biology and chemistry·2026
Same author

Role of analytical chemistry in the development of magnetoliposomes: Current and emerging techniques.

Analytica chimica acta·2026
Same author

Protein A/G-based microfluidic platform for preparative microseparation of IgG from human serum.

Talanta·2026
Same author

Development of a light-induced gas phase nitric oxide generator and its use in killing biofilm bacteria in vitro and ex vivo.

Journal of controlled release : official journal of the Controlled Release Society·2025

Related Experiment Video

Updated: May 2, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
08:01

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection

Published on: December 15, 2015

7.3K

Polyion selective polymeric membrane-based pulstrode as a detector in flow-injection analysis.

Andrea K Bell-Vlasov1, Joanna Zajda, Ayman Eldourghamy

  • 1Department of Chemistry, University of Michigan , 930 N. University, Ann Arbor, MI 48109-1055, United States.

Analytical Chemistry
|March 22, 2014
PubMed
Summary
This summary is machine-generated.

This study introduces a novel method for detecting polyions using specialized polymeric membrane electrodes in flow-injection analysis. This technique allows for the rapid, real-time detection of both polycations and polyanions with high reproducibility.

More Related Videos

Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
08:06

Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone

Published on: February 23, 2017

7.9K
Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor
09:49

Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor

Published on: April 6, 2016

7.3K

Related Experiment Videos

Last Updated: May 2, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
08:01

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection

Published on: December 15, 2015

7.3K
Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
08:06

Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone

Published on: February 23, 2017

7.9K
Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor
09:49

Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor

Published on: April 6, 2016

7.3K

Area of Science:

  • Analytical Chemistry
  • Electrochemistry
  • Polymer Science

Background:

  • Polyion detection is crucial in various scientific fields.
  • Existing methods for polyion detection can be complex or time-consuming.
  • Flow-injection analysis (FIA) offers a platform for rapid sample processing.

Purpose of the Study:

  • To develop and validate a novel method for detecting polyions using polymeric membrane electrodes in an FIA system.
  • To optimize the detection parameters for reproducible and real-time analysis.
  • To demonstrate the versatility of the detector for both polycations and polyanions.

Main Methods:

  • Utilized a plasticized polymeric membrane electrode doped with tridodecylmethylammonium-dinonylnaphthalene sulfonate (TDMA/DNNS) ion-exchanger salt.
  • Employed a pulse sequence including galvanostatic, open-circuit, and potentiostatic pulses for detection and membrane regeneration.
  • Optimized pulse sequence times for efficient analysis within a flow-injection analysis (FIA) system.

Main Results:

  • Achieved reproducible real-time detection of protamine and heparin at rates up to 20 samples per hour.
  • Demonstrated the ability to detect both polycations (≥10 μg/mL) and polyanions (≥40 μg/mL) using the same membrane detector by altering the galvanostatic pulse direction.
  • Established optimized pulse sequence times for effective sample analysis.

Conclusions:

  • The developed method provides a robust and efficient approach for polyion detection in FIA.
  • The reversible polymeric membrane electrode offers a versatile platform for detecting a wide range of polyionic species.
  • This methodology holds potential for application in other flowing systems like liquid chromatography and capillary electrophoresis.