Reduction of ICD shock burden by eliminating back-up pacing induced ventricular tachyarrhythmias
Cathrin Theis1, Hanke Mollnau1, Sebastian Sonnenschein1
1II. Medical Clinic, Department of Electrophysiology, University Medical Center, Johannes Gutenberg-University, Mainz, Germany.
Introduction:
Implantable cardioverter defibrillators (ICD) may have the capacity to provoke or worsen ventricular tachyarrhythmias (VT). It has been reported that ICD shocks by itself can increase mortality. This study aimed to determine the role of back-up pacing-induced VT (PIT) in the overall ICD shock burden by avoiding pause-related ventricular back-up pacing.
Methods And Results:
A population of 550 single-chamber ICD patients was studied. Of them, 17 (3%, 69 ± 16 years, 14 male) patients had documented episodes of PIT. A total of 431 VT episodes were documented including 89 (21%) due to PIT. In 3 patients, VT events were exclusively PITs. After ≥2 documented PITs, the pacing output for VVI pacing was set to a subthreshold level resulting in noncapturable ventricular back-up pacing. All other device parameters remained unchanged to prove a potential proarrhythmic effect of pause related back-up pacing. During a follow-up of 99 ± 39 months after reducing the pacing output to a subthreshold level, no further episodes of PIT were observed (P < 0.001). Moreover, with the prevention of PITs, the ICD shock burden decreased significantly (pre: 150 vs. post: 18, P < 0.001). However, a single event of pause-induced VT occurred due to missing back-up pacing.
Conclusions:
PIT is a frequent mechanism of VTs in ICD patients resulting in a substantially increased shock burden. Elimination of pause-related back-up pacing by subthreshold pacing output effectively abolishes PIT and thus significantly reduces ICD shock burden.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Dysrhythmias VI: Management of Dysrhythmias
Cardiopulmonary Resuscitation IV: Pharmacological Management
Cardiomyopathy V: Interprofessional Care
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy III: Hypertrophic Cardiomyopathy
