Related Experiment Video
Updated: May 1, 2026

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples
Published on: June 19, 2018
First TDCR measurements at low energies using a miniature x-ray tube
1CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), 91191 Gif-sur-Yvette Cedex, France; CEA, List, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex, France.
Abstract:
Developed for radionuclide standardization using liquid scintillation, the Triple to Double Coincidence Ratio (TDCR) method is applied using coincidence counting obtained with a specific three-photomultiplier system. For activity determination, a statistical model of light emission is classically used to establish a relation between the detection efficiency and the experimental TDCR value. At LNE-LNHB, a stochastic approach of the TDCR modeling was developed using the Monte Carlo code Geant4. The interest of this TDCR-Geant4 model is the possibility to simulate the propagation of optical photons from their creation in the scintillation vial to the production of photoelectrons in photomultipliers. As an alternative to the use of radionuclide sources, first TDCR measurements are presented using a miniature x-ray tube closely coupled to the scintillation vial. The objective of this new set-up was to enable low-energy depositions (lower than 20 keV) in liquid scintillator in order to study the influence of both time and geometrical dependence between PMTs already observed with radioactive sources. As for the statistical TDCR model, the non-linearity of light emission is implemented in the TDCR-Geant4 model using the Birks formula which depends on the kB factor and the scintillation yield. Measurements performed with the x-ray tube are extended to the assessment of these parameters and they are tested afterwards in the TDCR-Geant4 model for activity measurements of (3)H.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
Related Concept Videos
Determination of Crystal Structures
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...