Study of the TOFPET2c ASIC in time-of-flight detection of x-rays for scatter rejection in medical imaging
L-D Gaulin1,2, V Nadig3, K Herweg3
1Interdisciplinary Institute for Technological Innovation (3iT), Université de Sherbrooke, Sherbrooke, Québec, Canada.
Abstract:
Objective.Integrating time-of-flight (ToF) measurements in radiography and computed tomography (CT) enables an approach for scatter rejection in imaging systems that eliminates the need for anti-scatter grids, potentially increasing system sensitivity and image quality. However, present hardware dedicated to the time-correlated measurement of x-rays is limited to a single pixel physically too large for the desired spatial resolution. A switch to highly integrated electronics and detectors is needed to progress towards detector arrays capable of acquiring images, while offering a timing resolution below 300 ps FWHM to achieve scatter rejection comparable to current anti-scatter grids.Approach.Using off-the-shelf scintillators, photodetectors and readouts designed for ToF positron emission tomography (PET) provides a preliminary evaluation of available highly integrated readout systems supporting detector arrays for ToF scatter rejection. The TOFPET2c ASIC from PETSys offers an established development platform necessary for fast and reliable results, with no known limitation regarding time-correlated detection of medical imaging x-rays (20-140 keV).Main results.Reliable photon detection down to 31 keV was achieved, reaching energy resolutions from 23% to 92% FWHM throughout the desired energy range. Optimal detector timing resolution (DTR) from 250 ps FWHM at 130 keV to 678 ps FWHM at 30 keV was reached. Strong time walk effects were observed, showing a time shift of 642 ps up to 1740 ps between events spanning the energies used in x-ray medical imaging.Significance.The TOFPET2c ASIC has shown its potential for ToF scatter rejection, but meets the time resolution requirement of 300 ps FWHM only for limited energies (110-140 keV). This significant timing degradation observed at lower energies limits the use of the TOFPET2c ASIC for ToF scatter rejection, but offers significant advancements regarding the understanding of the phenomenon arising from the time-correlated detection of medical imaging x-rays.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...