A Two-stage Peak Alignment Algorithm for Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry-Based
1The Advanced Research Institute of Intelligent Sensing Network, Tongji University, shanghai, 201804, China ; The Key Laboratory of Embedded System and Service Computing, Ministry of Education, Tongji University, Shanghai 201804, China ; School of Electronics and Information Engineering, Tongji University, Shanghai 201804, China.
Abstract:
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC×GC/TOF-MS) has been applied to metabolomics analyses recently. However, retention time shifts in the two-dimensional gas chromatography will introduce difficulty to compare compound profiles obtained from multiple samples. In this work, a novel two-stage peak alignment algorithm has been developed for data analysis of GC×GC/TOF-MS. In the first stage, our algorithm detects and merges multiple peak entries of the same metabolite into one peak entry. After a z-score transformation of metabolite retention times, landmark peaks will be selected from all samples based on both two-dimensional retention times and mass spectrum similarity of fragment ions measured by Pearson's correlation coefficient. In the second stage, the original two-dimensional retention time shift will be corrected using a local linear fitting method. A progressive retention time map searching method is used to align peaks in all samples together based on the parameters optimized in the first stage. Our algorithm can avoid defining a threshold of retention time window and spectrum similarity, which is very difficult for the users since the experimental condition is always changed in different experimental runs, even for the repeat experiments. The experimental results show that our algorithm can work well in peak alignment from real biological samples, which is very important for the further analysis.
More Related Videos
07:21Preparation of Drosophila Larval Samples for Gas Chromatography-Mass Spectrometry GC-MS-based Metabolomics
Published on: June 6, 2018
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume