Related Experiment Video
Updated: May 1, 2026

Determining Viral Disinfection Efficacy of Hot Water Laundering
Published on: June 21, 2022
Experience in using thermal disinfection to remove viable bacteria and endotoxins in centraly distributed reverse
Ahmed Alayoud1, Mohamed Amine Hamzi1, Abdelaziz Razkaoui2
1Service of Nephrology, Hemodialysis and Kidney Transplantation, Military Hospital, Mohammed V. Rabat, Morocco.
Introduction:
The water used for dilution of hemodialysis concentrates has to meet official quality recommendations regarding microbiology and chemical parameters. To avoid chemical use and to simplify treatments, hot water has been used to control microbial contamination of water distribution systems. In this study we evaluated the efficacy of heat disinfection in maintaining the quality of dialysis water generated by reverse osmosis (RO).
Methods:
During the first part of the study, we consecutively used (1) continuous water circulation, (2) daily heat disinfection and (3) a combination of daily heat disinfection and weekly chemical disinfection while checking bacterial count and endotoxin level every 4-5 weeks. During the second part of the study, we continued using daily heat disinfection while checking bacterial count and endotoxin level on weekly basis.
Results:
The endotoxin levels at all sampling points of the water treatment system were lower than 0.005/ ml throughout the study. The application of heat disinfection alone reduced bacterial levels but an escape phenomenon occurred. After an interval of 21 days, an exponential increase of bacterial count was noted and cultures from the RO unit revealed growth of Pseudomonas fluorescence. The addition of chemical disinfection was successful in eliminating micro-organisms. Throughout this study, micro-organisms and endotoxins were not detectable in dialysate fluid and substitution fluid in dialysis monitors.
Conclusion:
The isolation of a thermo-sensitive organism from the RO unit after a period of relying on thermal disinfection suggests the existence of dead space in the RO unit that is not adequately exposed to heat but is accessible to chemical disinfection. .
More Related Videos
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...