Introduction:
Twenty-five cases of airway fire during tracheostomy have been reported in the literature. The authors describe a case observed in their centre 3 years ago, discuss the causes and preventive management and propose guidelines for prevention of this complication.
Case Report:
A 66-year-old woman was intubated and ventilated with 100% oxygen during general anaesthesia for tracheostomy. On opening the trachea by monopolar diathermy, the oxygen present in the endotracheal tube caught fire, inducing combustion of the tube spreading to the lower airways. This airway fire was responsible for severe acute respiratory failure and the formation of multiple laryngotracheal stenoses.
Discussion:
Combustion of the endotracheal tube due to ignition of anaesthetic gases induced by the heat generated by diathermy is responsible for airway fire. These various phenomena are discussed. Prevention is based on safety measures and coordination of surgical and anaesthetic teams.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...