Handling interferences in ⁸⁹Sr and ⁹⁰Sr measurements of reactor coolant water: a method based on strontium separation
S Holmgren1, A Tovedal1, S Jonsson1
1Swedish Defence Research Agency, SE-901 82 Umeå, Sweden.
Abstract:
Measurements for determining the activity of (89)Sr and (90)Sr in reactor coolant water are associated with limitations due to interferences from radionuclides with similar chemical properties and β(-)-energies. From a measurement bias point-of-view these interferences would result mainly in an overestimated activity concentration of (90)Sr. In order to address the interference problem, a common and well-known method was used in order to show the need for sufficient decontamination. An improvement was achieved by taking the sample through two initial strontium separations in order to increase the decontamination factor. This method determines the activity concentration of (89)Sr and (90)Sr, via its daughter nuclide (90)Y, by Cherenkov counting. This work is primarily based on theoretical calculations of strontium-, yttrium- and other potential interfering radionuclide ratios after instant fission. The work done to confirm the theoretical calculations were carried through on spiked strontium standard solutions and fresh reactor coolant water. The reactor coolant water was known to contain interferences at a composition resembling that of instant fission. The detection limit for double separation was calculated to 0.17 Bq/kg for (90)Sr and 0.38 Bq/kg for (89)Sr. When using methods that solely rely on strontium resins, this paper shows that the decontamination factor (DF) is significantly higher when using double separation than that of a single separation. The paper also shows that the DF of an initial double strontium separation is as effective when it comes to removing high ratio interferences as separations done with both Sr- and Ln-resin (EiChrom Technologies, Inc., 2003; Tovedal et al., 2009b). However, 'old' samples, where e.g. (140)Ba and (89)Sr has decayed, does not benefit from double separation. Furthermore, samples with low ratios of interfering radionuclides does not benefit from using this method either, seeing as this is a more time consuming method due to the double separations.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Precipitation and Co-precipitation
Qualitative Analysis
For instance, group IV...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...