A method to assess the accuracy of sonotubometry for detecting Eustachian tube openings
J Douglas Swarts1, Miriam S Teixeira, Juliane Banks
1Department of Otolaryngology, University of Pittsburgh, School of Medicine, Pittsburgh, PA, USA, dswarts@pitt.edu.
Abstract:
Sonotubometry is a simple test for Eustachian tube (ET) opening during a maneuver. Different sonotubometry configurations were suggested to maximize test accuracy, but no method has been described for comparing sonotubometry test results with those for a definitive measure of ET opening. Here, we present such a method and exemplify is use by an accuracy assessment of a simple sonotubometry configuration. A total of 502 data-sequences from 168 test sessions in 103 adult subjects were analyzed. For each session, subjects were seated in a pressure chamber and relative middle ear over- and under-pressures created by changing chamber pressure. At each pressure, the test sequence of bilateral tympanometry, bilateral sonotubometry while the subject swallowed twice, and bilateral tympanometry was done. Tympanometric data were expressed as the fractional gradient equilibrated (FGE) by swallowing and sonotubometric signals were analyzed to record the shape of detected sound signals. Tympanometric and sonotubometric tubal opening assignments were analyzed by cross-correlation. For the data sequences with FGE = 0 (n = 32) evidencing no tubal opening and one (n = 249) evidencing definitive tubal opening, detection of a sonotubometry sound signal during a swallow had a sensitivity and specificity of 74.2 and 65.6 % for identifying ET openings and an accuracy of 73.3 % for assigning ET opening/non-opening by swallowing. Measures of sound signal shape were significantly different between those groups. This protocol allows a sonotubometry accuracy assessment for detecting ET openings. For the test configuration used, accuracy was moderate, but this should improve as more sophisticated sonotubometry test configurations are evaluated.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...