Abstract:
A novel fluorimetric method based on diazotization-coupling reaction (DCR) for the determination of clenbuterol is described. In acidic solution, clenbuterol was first diazotized with sodium nitrite, followed by coupling with bisphenol A to produce an azo-compound in NH3- NH4Cl buffer. It has found the diazotized clenbuterol- bisphenol A- NH3- NH4Cl (DCBN) system has strong fluorescence efficiency compare with the bisphenol A solution. There is a linear relationship between the increased intensity of the fluorescence emission spectra (λex/λem = 276 nm/306 nm) and the concentration of clenbuterol. The effects of the amount of sodium nitrite, diazo reaction time, the amount of bisphenol A, coupling reaction time and coupling reaction temperature have been examined. Under the optional conditions, clenbuterol can be determined over the concentration range of 0.02 to 2.0 μg mL(-1) with a correlation coefficient of 0.9953. The detection limit is 0.01 μg mL(-1) at a signal-to-noise ratio of 3. The relative standard deviation (RSD) for 11 repetitive determinations of 0.9 μg mL(-1) clenbuterol is 0.22 %. The utility of this method was demonstrated by determining clenbuterol in meat samples.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Flame Photometry: Lab
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...