Human internal jugular valve M-mode ultrasound characterization
Erica Menegatti, Mirko Tessari, Sergio Gianesini
1Vascular Diseases Center - University of Ferrara, Via Aldo Moro 8, 44124 Cona (FE), Italy. menegatti.erica@gmail.com.
The internal jugular vein (IJV) valve mechanism remains unclear. Ultrasound reveals IJV valves are mobile but often absent, especially in upright positions, suggesting reduced physiological importance.
Area of Science:
- Vascular Ultrasound
- Human Physiology
- Anatomy
Background:
- The precise mechanism of internal jugular vein (IJV) valve function in humans is not well understood.
- While M-mode ultrasound is standard for cardiac valves, its application to IJV valves is novel.
- Previous assessments have not utilized M-mode for IJV valve evaluation.
Purpose of the Study:
- To investigate the physiology of internal jugular vein valves in healthy volunteers.
- To assess IJV valve characteristics using B-mode and M-mode ultrasound.
- To understand the impact of posture and cardiac cycle on IJV valve dynamics.
Main Methods:
- Eighty-three healthy volunteers (35 male, 48 female) underwent high-resolution B-mode and M-mode ultrasound of 166 IJVs.
- Evaluations were conducted under standardized postural and respiratory conditions.
- Assessment included valve presence, cusp number, motility, and opening/closure mechanisms.
Main Results:
- Bilateral IJV valve absence was noted in 16% of subjects, with at least one absent in 46%.
- Valve leaflets were mobile, predominantly bicuspid (34%) or unicuspid (27%), with unicuspid valves more frequent on the left.
- In supine position, valves opened synchronously with the cardiac cycle; in upright position, valves remained open and apposed to the wall.
Conclusions:
- Internal jugular vein valve leaflets are mobile, but a high rate of absence suggests potential phylogenetic loss of function.
- M-mode ultrasound provides enhanced characterization of IJV valves.
- Routine addition of M-mode ultrasound to cerebral venous return investigations is recommended.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Mitral Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests