Related Experiment Video
Updated: May 1, 2026

07:15
Transient Optical Clearing Using Absorbing Molecules for Ex Vivo and In Vivo Imaging
Published on: July 11, 2025
3.8K
Adaptive total variation minimization-based image enhancement from flash and no-flash pairs
Sang Min Yoon1, Yeon Ju Lee2, Gang-Joon Yoon2
1School of Computer Science, Kookmin University, 77 Jeongneung-ro, Seogbuk-gu, Seoul 136-702, Republic of Korea.
Thescientificworldjournal
|April 10, 2014
Summary
This study introduces a new method to improve image quality using flash and no-flash photos. The technique combines ambient light from one image with flash details from another for enhanced results.
Area of Science:
- Computer Vision
- Image Processing
- Computational Photography
Background:
- Image quality is often degraded by noise or lack of detail.
- Capturing images with both flash and no-flash provides complementary information.
- Combining information from multiple images is a key challenge in image enhancement.
Purpose of the Study:
- To develop a novel image enhancement technique.
- To improve image quality by merging flash and no-flash image data.
- To achieve efficient image denoising while preserving important image details.
Main Methods:
- A novel approach combining flash and no-flash images.
- Utilizing Adaptive Total Variation Minimization (ATVM).
- Preserving strong gradients in the flash image for detail retention.
Main Results:
- The proposed method effectively enhances image quality.
- Demonstrated efficient image denoising capabilities.
- Successfully preserved strong image gradients.
Conclusions:
- The novel approach offers a significant improvement in image enhancement.
- Adaptive Total Variation Minimization proves effective for denoising.
- The technique successfully merges ambient light and flash details for superior image quality.
Related Concept Videos
Super-resolution Fluorescence Microscopy
12.3K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.3K
Phase Contrast and Differential Interference Contrast Microscopy
9.4K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
9.4K
Difference from Background: Limit of Detection
9.0K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
9.0K

