Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Titanium (III) cation selective electrode based on synthesized tris(2pyridyl) methylamine ionophore and its
Majid Rezayi1, Reza Karazhian2, Yadollah Abdollahi3
11] Chemistry Department, Faculty of Science, University Malaya, 50603 Kuala Lumpur, Malaysia [2] Food Quality and Safety Research Department, Food Science and Technology Research Institute, ACECR Mashhad Branch, 91775-1376 Mashhad, Iran.
Abstract:
The introduction of low detection limit ion selective electrodes (ISEs) may well pave the way for the determination of trace targets of cationic compounds. This research focuses on the detection of titanium (III) cation using a new PVC-membrane sensor based on synthesized tris(2pyridyl) methylamine (tpm) ionophore. The application and validation of the proposed sensor was done using potentiometric titration, inductively coupled plasma atomic emission spectrometry (ICP-AES), and atomic absorption spectrometry (AAS). The membrane sensor exhibited a Nernstian response to the titanium (III) cation over a concentration range of 1.0 × 10(-6)-1.0 × 10(-2) M and pH range from 1-2.5. The Nernstian slope, the lower of detection (LOD), and the response time (t95%) of the proposed sensor were 29.17 ± 0.24 mV/dec, 7.9 × 10-7 M, and 20 s, respectively. The direct determination of 4-39 μg/ml of titanium (III) standard solution showed an average recovery of 94.60 and a mean relative standard deviation of 1.8 at 100.0 μg/ml. Finally, the utilization of the electrodes as end-point indicators for potentiometric titration with EDTA solutions for titanium (III) sensor was successfully carried out.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
08:34A Dual-Functional Electroactive Filter Towards Simultaneously SbIII Oxidation and Sequestration
Published on: December 5, 2019
Related Concept Videos
Potentiometry: Membrane Electrodes
EDTA: Indirect and Alkalimetric Titration
EDTA: Chemistry and Properties
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...