Background:
Appropriate use criteria for cardiovascular imaging have been published, but compliance in practice has been incomplete, with persistent high rates of inappropriate use. The aim of this study was to show the efficacy of a continuous quality improvement (CQI) initiative to favorably influence the appropriate use of outpatient transthoracic echocardiography and single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (MPI) in a large cardiovascular practice.
Methods:
In this prospective study, a multiphase CQI initiative was implemented, and its impact on ordering patterns for outpatient transthoracic echocardiography and SPECT MPI was assessed. Between November and December 2010, a baseline analysis of the application of appropriate use criteria to indications for outpatient transthoracic echocardiographic studies (n = 203) and SPECT MPI studies (n = 205) was performed, with studies categorized as "appropriate," "inappropriate," "uncertain," or "unclassified." The CQI initiative was then begun, with (1) clinician education, including didactic lectures and case-based presentations with audience participation; (2) system changes in ordering processes, with redesigned image ordering forms; and (3) peer review and feedback. A follow-up analysis was then performed between June and August 2012, with categorization of indications for transthoracic echocardiographic studies (n = 206) and SPECT MPI studies (n = 206).
Results:
At baseline, 73.9% of echocardiographic studies were categorized as appropriate, 16.7% as inappropriate, 5.9% as uncertain, and 3.4% as unclassified. Similarly, for SPECT MPI studies 71.7% were categorized as appropriate, 18.5% as inappropriate, 7.8% as uncertain, and 1.9% as unclassified. Separate analysis of the two most important categories, appropriate and inappropriate, demonstrated a significant improvement after the CQI initiative, with a 63% reduction in inappropriate echocardiographic studies (18.5% vs 6.9%, P = .0010) and a 46% reduction in inappropriate SPECT MPI studies (20.5% vs 11.1%, P = .010).
Conclusions:
This study demonstrates the effective and persistent positive impact of a CQI initiative to reduce inappropriate ordering of cardiovascular imaging.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies