Related Experiment Video
Updated: May 1, 2026

A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
Published on: April 21, 2017
Accuracy of three activity monitors in patients with chronic obstructive pulmonary disease: a comparison with video
Mikael Andersson1, Christer Janson, Margareta Emtner
11Department of Neuroscience, Physiotherapy, Uppsala University , Uppsala , Sweden.
Abstract:
Low physical activity and sedentary behaviour characterise the lives of patients with chronic obstructive pulmonary disease (COPD). Using activity monitors, assessment of both aspects are possible, but many outcomes are not well validated. The aim of this study was to assess the accuracy and equivalency of three activity monitors regarding steps, body position and their ability to differentiate between periods of physical activity and inactivity. Fifteen patients with COPD (8 females; median (interquartile range, IQR) age, 64 (59-69) years; forced expiratory volume in 1 second, 37 (28-48)% predicted; 6-minute walk distance, 444 (410-519) m) were enrolled. The DynaPort ADL-monitor, the DynaPort MiniMod monitor and the SenseWear Armband Pro 3 monitor were assessed. Subjects performed a structured protocol alternating physical activity and inactivity while simultaneously wearing all three monitors and being video recorded. The mean difference (limits of agreement) in step count from monitors compared to manual step count was -69 (-443 to 305) for the ADL-monitor, -19 (-141 to 103) for the MiniMod and -479 (-855 to -103) for the SenseWear Armband. Compared to the video, the sitting time was 97 (94-100)% when measured by the ADL-monitor and 121 (110-139)% by the MiniMod. Standing time was 114 (107-122)% when measured by the ADL-monitor and 68 (47-106)% by the MiniMod. Activity monitors are not equivalent in their abilities to detect steps or body positions. The choice of monitor should be based on the particular outcome of interest.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
05:59Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
Published on: March 7, 2019
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Holter Monitor: 24-Hour Monitoring
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...