Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Diagnostic value of elastography using acoustic radiation force impulse imaging and strain ratio for breast tumors
Yoon Seok Kim1, Jung Gu Park2, Beom Su Kim2
1Department of Surgery, Kosin University Gospel Hospital, Busan, Korea.
Purpose:
The aim of this study was to determine whether the combination of B-mode ultrasonography (BUS), acoustic radiation force impulse (ARFI) elastography, and strain ratio (SR) provides better diagnostic performance of breast lesion differentiation than BUS alone.
Methods:
ARFI elastography and SR evaluations were performed on patients with 157 breast lesions diagnosed by BUS from June to September 2013. BUS images were classified according to the Breast Imaging-Reporting and Data System. ARFI elastography was performed using Virtual Touch™ tissue imaging (VTI) and Virtual Touch™ tissue quantification (VTQ). In VTI mode, we evaluated the color-mapped patterns of the breast lesion and surrounding tissue. The lesions were classified into five categories by elasticity score. In VTQ mode, each lesion was assessed using shear wave velocity (SWV) measurements. SR was calculated from the lesion and comparable lateral fatty tissue. We compared the diagnostic performance of BUS alone and the combination of BUS, ARFI elastography, and SR evaluations.
Results:
Among the 157 lesions, 40 were malignant and 117 were benign. The mean elasticity score (3.7±1.0 vs. 1.6±0.8, p<0.01), SWV (4.23±1.09 m/sec vs. 2.22±0.88 m/sec, p<0.01), and SR (5.69±1.63 vs. 2.69±1.40, p<0.01) were significantly higher for malignant lesions than benign lesions. The results for BUS combined with ARFI elastography and SR values were 97.5% sensitivity, 92.3% specificity, 93.6% accuracy, a 79.6% positive predictive value (PPV), and a 99.1% negative predictive value. The combination of the 3 radiologic examinations yielded superior specificity, accuracy, and PPV compared to BUS alone (p<0.01 for each).
Conclusion:
ARFI elastography and SR evaluations showed significantly different mean values for benign and malignant lesions. Moreover, these two modalities complemented BUS and improved the diagnostic performance of breast lesion detection. Therefore, ARFI elastography and SR evaluations can be used as complementary modalities to make more accurate breast lesion diagnoses.
More Related Videos
12:18Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
Published on: February 9, 2012
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography