High-resolution transmission electron microscopy of isolated fullerene C60 molecules
Journal of Nanoscience and Nanotechnology
|April 22, 2014
Abstract:
Isolated fullerene C60 molecules on the surfaces of C60 crystals were observed by high-resolution transmission electron microscopy. The observed images were compared with the simulated images. It was found that the orientation of the observed C60 molecules can be identified.
Related Concept Videos
Transmission Electron Microscopy
6.1K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
6.1K
Overview of Electron Microscopy
11.7K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
11.7K
Super-resolution Fluorescence Microscopy
12.3K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.3K
Cryo-electron Microscopy
3.2K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
3.2K
Studying the Cytoskeleton
8.3K
The cytoskeletal architecture can be studied using different microscopic and biochemical techniques. Electron microscopy was instrumental in discovering the cytoskeletal architecture around the 1960s, which allowed obtaining structural information at a high-resolution level. However, the sample preparation procedure often limits this ability in biological samples. Several protocols have been developed over the years to optimize sample preparation. In one of the protocols known as rotary...
8.3K