Refinement of an instrument for assessing incontinent-associated dermatitis and its severity for use with
Donna Zimmaro Bliss1, Jennifer Hurlow, Jean Cefalu
1Donna Zimmaro Bliss, PhD, RN, FAAN, FGSA, Professor and School of Nursing Foundation Professor of Nursing Research, the School of Nursing University of Minnesota, Minneapolis. Jennifer Hurlow, GNP-BC, CWOCN, Wound Practitioner LLC, Germantown, Tennessee. Jean Cefalu, MSN, A/GNP-c, CWOCN, CFCN, CNE, Instructor of Nursing, Louisiana State University Health Sciences Center, New Orleans. Leigh Mahlum, BA, College of Liberal Arts, University of Minnesota, Minneapolis. Kathleen Borchert, RN, MS, CWOCN, Advanced Practice Nurse, HealthEast Bethesda Hospital, St. Paul, Minnesota. Kay Savik, MS, Senior Research Associate and Biostatistician, School of Nursing, University of Minnesota, Minneapolis.
Purpose:
The purpose of this study was to refine an instrument for assessing incontinence-associated dermatitis (IAD) and its severity for use on lighter- and darker-toned skin, the Incontinence-Associated Dermatitis and its Severity Instrument-D (IADS-D), and to test its validity and reliability among WOC nurses.
Methods:
Revisions to the existing instrument included examples of colors of normal and IAD-damaged skin that would be observed on light-, medium-, and dark-toned skin using pixels from patient photographs, additional photographs of IAD manifestations on different skin tones, and training materials. Four certified WOC nurse consultants and 2 WOC nurse clinical experts assessed the face and content validity of the IADS-D instrument. The IADS-D instrument was tested for criterion validity and interrater reliability using photo cases by attendees at the Wound, Ostomy, and Continence Nurses Society 2012 conference.
Results:
The IADS-D instrument had good face and content validity. The overall average intraclass correlation coefficient (ICC) of IADS-D scores for all photo cases of testers (n = 266, 95% female, age 53.0 ± 7.9 years, mean ± SD) and those of investigators, experts, and consultants serving as the criterion was 0.90. The overall ICC for interrater reliability between all nurse testers was 0.99 and the ICC for tester skin tone was 0.99.
Conclusion:
The IADS-D instrument has excellent validity and interrater reliability among WOC nurses. Its refinement for use with lighter- and darker-toned skin addresses the lack of a much-needed instrument in nursing practice and research. Results support continued development and evaluation of the instrument's use in clinical and research settings.
More Related Videos
06:31Precision Implementation of Minimal Erythema Dose MED Testing to Assess Individual Variation in Human Inflammatory Response
Published on: October 3, 2019
09:32Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
Related Concept Videos
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Changes in Skin Color: Clinical Perspectives
Albinism
Albinism is a genetic disorder that affects (completely or partially) the coloring of skin, hair, and eyes. The defect is primarily...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...