Fluorescein dye intercalated layered double hydroxides for chemically stabilized photoluminescent indicators on

Jong Hyeon Lee1, Duk-Young Jung, Eunchul Kim

  • 1Department of Chemistry, The Catholic University of Korea, Bucheon, Gyeonggi 420-743, Korea.

Related Concept Videos

Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K
Labeling DNA Probes03:31

Labeling DNA Probes

DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
7.7K
Immunofluorescence Microscopy01:12

Immunofluorescence Microscopy

A fluorescence microscope uses fluorescent chromophores called fluorochromes, which can absorb energy from a light source and then emit this energy as visible light. Fluorochromes include naturally fluorescent substances (such as chlorophylls) and fluorescent stains that are added to the specimen to create contrast. Dyes such as Texas red and FITC are examples of fluorochromes. Other examples include the nucleic acid dyes 4’,6’-diamidino-2-phenylindole (DAPI), and acridine orange.
11.1K
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
11.0K
Photoluminescence: Fluorescence and Phosphorescence01:23

Photoluminescence: Fluorescence and Phosphorescence

Photoluminescence is a process where a molecule absorbs light energy and re-emits it in the form of light. This phenomenon occurs when a substance absorbs photons, promoting its electrons to higher energy level excited states, followed by a relaxation process in which the electrons return to their original ground state energy levels and emit light. Photoluminescence is widely observed in various materials, including semiconductors, and organic and inorganic compounds.
A pair of electrons in a...
5.6K
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
1.9K