Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

First Order Systems01:21

First Order Systems

593
First-order systems, such as RC circuits, are foundational in understanding dynamic systems due to their straightforward input-output relationship. Analyzing their responses to different input functions under zero initial conditions reveals significant insights into system behavior.
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
593
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model01:13

Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model

427
Drugs administered through various routes can lead to nonlinear elimination, resulting in complex pharmacokinetic behaviors crucial to understanding efficacious drug dosing.
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
427
Elimination Kinetics: First-Order and Zero-Order01:05

Elimination Kinetics: First-Order and Zero-Order

4.0K
Eliminating drugs from the body is a vital process that occurs through excretion or metabolism. Understanding the kinetics of drug elimination is crucial for drug development, dosage determination, and optimizing patient outcomes.
Drug clearance depends on the rate of drug elimination and its plasma concentration. Another important parameter is a drug's half-life, which is the time required for its concentration to decrease by half. In most cases, drug clearance follows first-order...
4.0K
Bode Plots Construction01:24

Bode Plots Construction

1.0K
The Bode plot is an essential tool in control system analysis, mapping the frequency response of a system through a magnitude plot and a phase plot, both against a logarithmic frequency axis. To construct a Bode plot, consider the transfer function H(ω):
1.0K
Second-Order Circuits01:17

Second-Order Circuits

4.5K
Integrating two fundamental energy storage elements in electrical circuits results in second-order circuits, encompassing RLC circuits and circuits with dual capacitors or inductors (RC and RL circuits). Second-order circuits are identified by second-order differential equations that link input and output signals.
Input signals typically originate from voltage or current sources, with the output often representing voltage across the capacitor and/or current through the inductor. For example, in...
4.5K
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

1.0K
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
1.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Integrating Upper-Limb Prostheses with the Human Body: Technology Advances, Readiness, and Roles in Human-Prosthesis Interaction.

Annual review of biomedical engineering·2024
Same author

Wrist speed feedback improves elbow compensation and reaching accuracy for myoelectric transradial prosthesis users in hybrid virtual reaching task.

Journal of neuroengineering and rehabilitation·2023
Same author

Neurorobotic fusion of prosthetic touch, kinesthesia, and movement in bionic upper limbs promotes intrinsic brain behaviors.

Science robotics·2021
Same author

An analytical method reduces noise bias in motor adaptation analysis.

Scientific reports·2021
Same author

Embodied Cooperation to Promote Forgiving Interactions With Autonomous Machines.

Frontiers in neurorobotics·2021
Same author

Joint speed feedback improves myoelectric prosthesis adaptation after perturbed reaches in non amputees.

Scientific reports·2021

Related Experiment Video

Updated: Apr 30, 2026

Measuring Neuromuscular Junction Functionality
10:40

Measuring Neuromuscular Junction Functionality

Published on: August 6, 2017

17.7K

Comparing functional EMG characteristics between zero-order and first-order interface dynamics.

Reva E Johnson, Jonathon W Sensinger

    IEEE Transactions on Neural Systems and Rehabilitation Engineering : a Publication of the IEEE Engineering in Medicine and Biology Society
    |April 25, 2014
    PubMed
    Summary

    A functional electromyographic (EMG) model for powered prostheses is valid across different control schemes. This model, using standard deviation, kurtosis, and median power frequency, remains consistent regardless of control order.

    More Related Videos

    Author Spotlight: Epimysial Electrode Fabrication and Testing in ACL Injury Studies
    04:48

    Author Spotlight: Epimysial Electrode Fabrication and Testing in ACL Injury Studies

    Published on: April 12, 2024

    1.1K
    Interfacing Microfluidics with Microelectrode Arrays for Studying Neuronal Communication and Axonal Signal Propagation
    11:27

    Interfacing Microfluidics with Microelectrode Arrays for Studying Neuronal Communication and Axonal Signal Propagation

    Published on: December 8, 2018

    7.6K

    Related Experiment Videos

    Last Updated: Apr 30, 2026

    Measuring Neuromuscular Junction Functionality
    10:40

    Measuring Neuromuscular Junction Functionality

    Published on: August 6, 2017

    17.7K
    Author Spotlight: Epimysial Electrode Fabrication and Testing in ACL Injury Studies
    04:48

    Author Spotlight: Epimysial Electrode Fabrication and Testing in ACL Injury Studies

    Published on: April 12, 2024

    1.1K
    Interfacing Microfluidics with Microelectrode Arrays for Studying Neuronal Communication and Axonal Signal Propagation
    11:27

    Interfacing Microfluidics with Microelectrode Arrays for Studying Neuronal Communication and Axonal Signal Propagation

    Published on: December 8, 2018

    7.6K

    Area of Science:

    • Biomedical Engineering
    • Rehabilitation Technology
    • Prosthetics and Orthotics

    Background:

    • Accurate modeling of prosthesis control is crucial for optimizing powered prosthetic devices.
    • Electromyographic (EMG) signals are widely used for intuitive control of prosthetic limbs.
    • Understanding EMG signal characteristics across different control schemes is essential for robust prosthetic design.

    Purpose of the Study:

    • To develop and validate a functional electromyographic (EMG) model for powered prostheses.
    • To investigate the impact of different control schemes (zero-order vs. first-order) on EMG signal characteristics.
    • To determine the generalizability of the developed EMG model across varying control strategies.

    Main Methods:

    • Collected EMG data under realistic, closed-loop, dynamic, and isometric contraction conditions.
    • Constructed a functional EMG model based on three key signal characteristics: standard deviation, kurtosis, and median power frequency.
    • Analyzed the statistical significance and effect size of control order on the identified EMG characteristics.

    Main Results:

    • A functional EMG model was successfully constructed using standard deviation, kurtosis, and median power frequency.
    • Control order demonstrated a statistically significant effect on EMG characteristics.
    • The observed effect size of control order was small and typically within the range of inter-subject variability.

    Conclusions:

    • The developed functional EMG model is robust and remains valid across different control schemes for powered prostheses.
    • The findings suggest that a single EMG model can be effectively utilized for various control strategies, simplifying prosthetic system development.
    • This research contributes to the advancement of more adaptable and user-friendly powered prosthetic control systems.