Related Experiment Video
Updated: Apr 30, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
The clinical value of (18)F-FDG detection with a dual-head coincidence camera: a review
1Department of Nuclear Medicine, Osmangazi University, Medical Faculty, Eskisehir, Turkey, Turkey.
Abstract:
Positron emission tomography (PET) has evolved into a technique that can accurately determine the distribution of positron-emitting radionuclides. The addition of a coincidence detection mode to a standard dual-head detector system has resulted in the option of single-photon and annihilation coincidence detection. This new device for imaging fluorine-18 2-fluoro-2-deoxy-D-glucose ((18)F-FDG) accumulation in neoplasms became commercially available in 1994. Besides conventional low-energy imaging in the collimated single-photon mode, it offers a relatively inexpensive opportunity to perform uncollimated PET by switching to the coincidence acquisition mode. This review summarises the clinical value of (18)F-FDG detection with a dual-head coincidence camera in oncology. The results are compared with the overall results obtained using dedicated PET scanners. With respect to head and neck tumours, (18)F-FDG coincidence mode gamma camera imaging (CGI) yields results that are in agreement with those obtained with dedicated PET scanners. With regard to other malignancies, such as lung cancer, lymphoma and brain tumours, data in the literature are too scarce to draw any definite conclusions. In general, the results of (18)F-FDG CGI in tumours >15 mm seem to be comparable to those obtained with dedicated PET scanners, whereas in tumours <15 mm, the relative sensitivity of (18)F-FDG CGI is approximately 80%. Using attenuation correction, the diagnostic yield of (18)F-FDG CGI may increase. However, further clinical investigation is required to definitely establish its value in staging primary disease, therapy monitoring and assessment of tumour recurrence in clinical oncology.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
![Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F62334.jpg&w=3840&q=50)
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)