Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
A unidirectional breathing pattern improves breathing efficiency in subjects with severe COPD
Demet S Sulemanji1, Fangping Bao2, Yandong Jiang1
1Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts.
Background:
Unidirectional breathing (UB), nose-in mouth-out (NMB) or vice versa, is thought to create PEEP, stabilize small airways, and increase expiratory flow and exhaled tidal volume (VT) in patients with expiratory obstructive disorders. However, the exact mechanism providing the benefits of UB remains unknown. Our hypothesis was that the benefits of UB are achieved mainly through reduction of upper airway dead space.
Methods:
Sixteen stable COPD patients requiring oxygen use at home were enrolled in this prospective study at a tertiary health care center. A nasal mask and a mouthpiece were used, each having a removable one-way valve to direct the breathing pattern. Four experimentally defined patterns of spontaneous breathing, NMB, mouth-in nose-out (MNB), nose-in nose-out (NNB), and mouth-in mouth-out (MMB), were compared. Each breathing pattern lasted 5 min followed by a 5-min rest period. A NICO device continuously monitored respiratory parameters. The functional anatomical dead space volume (VD) and expired VT values were determined. Breathing efficiency (BE) was calculated as alveolar VT divided by expired volume.
Results:
Functional anatomical VD was higher in bidirectional breathing (BB) (overall: 207.4 ± 7.9 mL; MMB: 232.5 ± 72.7 mL; NNB: 182.2 ± 75 mL) compared to UB (overall: 178.1 ± 87.2 mL; NMB: 176.9 ± 91.3 mL; MNB: 179.3 ± 83.2 mL) (P < .001). BE achieved with UB (overall: 76.2 ± 6.5%; NMB: 76.8 ± 6.8%; MNB: 75.6 ± 6.3%) was higher than that with BB (overall: 66.2 ± 0.09%; MMB: 64.3 ± 0.10%; NNB: 68.1 ± 0.08%) (P < .001). The difference in BE between UB and BB was more pronounced with small VT values (UB: 73.8 ± 0.08; BB: 49.4 ± 0.09) than with large VT values (UB: 77.3 ± 0.06; BB: 63.0 ± 0.07) (P < .001).
Conclusions:
Our data suggest that a reduction in functional anatomic VD may be the underlying mechanism for the benefits associated with UB in COPD patients. (ClinicalTrials.gov registration NCT00784004.).
More Related Videos
Related Concept Videos
COPD: Management Using Bronchodilators and Corticosteroids
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Chronic Obstructive Pulmonary Disease-I: Introduction