Related Experiment Video
Updated: Apr 30, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Determination of estrogens in environmental water samples using 1,3-dipentylimidazolium hexafluorophosphate ionic
Bárbara Socas-Rodríguez1, Javier Hernández-Borges, María Asensio-Ramos
1Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de La Laguna (ULL), La Laguna (Tenerife), Spain.
Abstract:
In this work, the potential of a symmetric dialkyl-substituted ionic liquid (IL), 1,3-dipenthylimidazolium hexafluorophosphate ([PPIm][PF6 ]), as extraction solvent in dispersive liquid-liquid microextraction (DLLME) has been studied for the analysis of a group of three natural (estriol, 17β-estradiol, and 17α-estradiol) and four synthetic (17α-ethynylestradiol, diethylstibestrol, dienestrol, and hexestrol) estrogenic compounds as well as one mycotoxin with estrogenic activity (zearalenone) in different types of water samples (Milli-Q, mineral, and wastewater). Separation, determination, and quantification were developed by HPLC-DAD and a fluorescence detector (FD) connected in series. Factors influencing the IL-DLLME procedure (sample pH, amount of IL, type and volume of disperser solvent, ionic strength, and assistance of vortex agitation) were investigated and optimized by means of a step-by-step approach. Once the optimum extraction conditions were established (10 mL of water at pH 8, 60 mg of [PPIm][PF6 ], 500 μL of ACN as disperser solvent and vortex agitation for 1 min), the calibration curves of the whole method (IL-DLLME-HPLC-DAD/FD) were obtained and precision and accuracy were evaluated. It was demonstrated that the developed methodology was repeatable, accurate, and selective with limits of detection in the 0.30-0.57 μg/L and 13.8-37.1 μg/L range for FD and DAD, respectively. Relative recovery values were higher than 85% for the different types of water samples and the Student's t test demonstrated that there were not significant differences between the added and the found concentration.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
14:13Detecting Estrogenic Ligands in Personal Care Products using a Yeast Estrogen Screen Optimized for the Undergraduate Teaching Laboratory
Published on: January 1, 2018
Related Concept Videos
Ion-Exchange Chromatography
Extraction: Advanced Methods
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...