Background:
Central venous pressure (CVP) is traditionally obtained through subclavian or internal jugular central catheters; however, many patients who could benefit from CVP monitoring have only femoral lines. The accuracy of illiac venous pressure (IVP) as a measure of CVP is unknown, particularly following laparotomy.
Methods:
This was a prospective, observational study. Patients who had both internal jugular or subclavian lines and femoral lines already in place were eligible for the study. Pressure measurements were taken from both lines in addition to measurement of bladder pressure, mean arterial pressure, and peak airway pressure. Data were evaluated using paired t-test, Bland-Altman analysis, and linear regression.
Results:
Measurements were obtained from 40 patients, 26 of which had laparotomy. The mean difference between measurements was 2.2 mm Hg. There were no significant differences between patients who had laparotomy and nonsurgical patients (P = 0.93). Bland-Altman analysis revealed a bias of 1.63 ± 2.44 mm Hg. There was no correlation between IVP accuracy and bladder pressure, mean arterial pressure, or peak airway pressure.
Conclusions:
IVP is an adequate measure of CVP, even in surgical patients who have had recent laparotomy. Measurement of IVP to guide resuscitation is encouraged in patients who have only femoral venous catheter access.
Related Concept Videos
Aneurysm IV: Nursing Management
Peripheral Artery Disease V: Postoperative Nursing Management
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...