Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

7.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.6K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.0K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

893
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
893
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

671
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
671

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Enhancing the OncoSim-Breast model using Canadian breast density information.

Health reports·2026
Same author

TMIST Lead-In Randomized Trial of Breast Tomosynthesis Versus Digital Mammography: Results in Women Ineligible for the Full TMIST Trial Due to Age (40-44 or ≥ 75 Years Old).

AJR. American journal of roentgenology·2026
Same author

More than density: validating a mammographic masking prediction model in Dutch breast cancer screening.

European radiology·2025
Same author

Intra-tumoral spatial heterogeneity in breast cancer quantified using high-dimensional protein multiplexing and single cell phenotyping.

Breast cancer research : BCR·2025
Same author

Cost-Effectiveness of Breast Cancer Screening Using Digital Mammography in Canada.

JAMA network open·2025
Same author

A Modified Bleaching Method for Multiplex Immunofluorescence Staining of FFPE Tissue Sections.

Applied immunohistochemistry & molecular morphology : AIMM·2024
Same journal

Orbital Imaging.

Radiologic clinics of North America·2026
Same journal

Imaging, Management, and Treatment of Orbital Trauma.

Radiologic clinics of North America·2026
Same journal

Imaging Findings after Multidisciplinary Treatment for Orbital and Ocular Adnexal Cancers.

Radiologic clinics of North America·2026
Same journal

Orbital Tumors: What the Radiologist Needs to Know from the Orbital Surgeon's Perspective.

Radiologic clinics of North America·2026
Same journal

Multidisciplinary Management of Tumors of the Orbit.

Radiologic clinics of North America·2026
Same journal

Skull Base, Bone, Pituitary-Regions around Orbit that Affect Vision.

Radiologic clinics of North America·2026
See all related articles

Related Experiment Video

Updated: Apr 30, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

2.6K

Digital tomosynthesis: technique.

Martin J Yaffe1, James G Mainprize1

  • 1Sunnybrook Research Insitute, 2075 Bayview Avenue, Toronto, ON M4N 3M5, Canada.

Radiologic Clinics of North America
|May 6, 2014
PubMed
Summary
This summary is machine-generated.

Digital breast tomosynthesis (DBT) improves on digital mammography by creating 3D images. Optimizing DBT involves adjusting factors like angular range, projection count, and dose for better image quality and reduced patient radiation exposure.

Keywords:
Digital mammographyDigital tomosynthesisOptimizationReconstruction

More Related Videos

Label-free, High-Resolution 3D Imaging and Machine Learning Analysis of Intestinal Organoids via Low-Coherence Holotomography
10:40

Label-free, High-Resolution 3D Imaging and Machine Learning Analysis of Intestinal Organoids via Low-Coherence Holotomography

Published on: August 12, 2025

1.9K
Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

13.2K

Related Experiment Videos

Last Updated: Apr 30, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

2.6K
Label-free, High-Resolution 3D Imaging and Machine Learning Analysis of Intestinal Organoids via Low-Coherence Holotomography
10:40

Label-free, High-Resolution 3D Imaging and Machine Learning Analysis of Intestinal Organoids via Low-Coherence Holotomography

Published on: August 12, 2025

1.9K
Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

13.2K

Area of Science:

  • Radiology and Medical Imaging
  • Biomedical Engineering

Background:

  • Digital breast tomosynthesis (DBT) is an advanced imaging technique extending digital mammography.
  • DBT utilizes low-dose x-ray projections over a limited angular range to reconstruct quasi-three-dimensional images.

Purpose of the Study:

  • To discuss key aspects of optimizing digital breast tomosynthesis.
  • To highlight the factors influencing image quality and radiation dose in DBT.

Main Methods:

  • The article reviews principles of image reconstruction in DBT.
  • It examines the impact of acquisition parameters on image fidelity and patient safety.

Main Results:

  • Image quality and breast dose are directly influenced by angular range and projection number.
  • Detector characteristics, including resolution and noise, are critical for optimal performance.

Conclusions:

  • Tomosynthesis optimization requires careful consideration of multiple technical parameters.
  • Balancing image quality with radiation dose is essential for effective breast cancer screening using DBT.