Short-term repeatability of electrocardiographic Tpeak-Tend and QT intervals
Kapuaola S Gellert1, Pentti Rautaharju2, Michelle L Snyder1
1Department of Epidemiology, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC.
Background:
The electrocardiographic (ECG) Tpeak-Tend interval (TpTe) is associated with arrhythmias and sudden cardiac death. TpTe offers a supplementary measure for the QT interval (QT), yet its repeatability has not been established.
Purpose:
Evaluate short-term repeatability of TpTe and QT.
Methods:
Four ECGs were obtained on sixty participants. The sources of variation, intra-class correlation coefficient (ICC) - an index of reproducibility - and minimal detectable change (MDC) were estimated for TpTe and QT. The impact of repeated measurements on repeatability was estimated for a hypothetical clinical trial designed to detect drug-induced prolongation of TpTe and QT.
Results:
We used heart rate-adjusted QT [(QT)a] but TpTe in the study group was rate-invariant. The ICC [95% confidence interval (CI)] was 0.77 (0.69, 0.85) for TpTe, 0.75 (0.65, 0.85) for QT and 0.60 (0.47, 0.73) for (QT)a. The MDC (ms) was 21, 32 and 26 for TpTe, QT and (QT)a respectively.
Conclusion:
TpTe has excellent repeatability supporting its use as a supplement to QT in observational and clinical studies.
More Related Videos
08:28Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
11:13Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
Published on: May 12, 2017
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias III: Characteristics of Dysrhythmias