Related Experiment Video
Updated: Apr 30, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Soft tissue integration versus early biofilm formation on different dental implant materials
Bingran Zhao1, Henny C van der Mei2, Guruprakash Subbiahdoss2
1University of Groningen and University Medical Center of Groningen, Department of Orthodontics, Hanzeplein 1, 9700 RB Groningen, The Netherlands.
Objective:
Dental implants anchor in bone through a tight fit and osseo-integratable properties of the implant surfaces, while a protective soft tissue seal around the implants neck is needed to prevent bacterial destruction of the bone-implant interface. This tissue seal needs to form in the unsterile, oral environment. We aim to identify surface properties of dental implant materials (titanium, titanium-zirconium alloy and zirconium-oxides) that determine the outcome of this "race-for-the-surface" between human-gingival-fibroblasts and different supra-gingival bacterial strains.
Methods:
Biofilms of three streptococcal species or a Staphylococcus aureus strain were grown in mono-cultures on the different implant materials in a parallel-plate-flow-chamber and their biovolume evaluated using confocal-scanning-laser-microscopy. Similarly, adhesion, spreading and growth of human-gingival-fibroblasts were evaluated. Co-culture experiments with bacteria and human-gingival-fibroblasts were carried out to evaluate tissue interaction with bacterially contaminated implant surfaces. Implant surfaces were characterized by their hydrophobicity, roughness and elemental composition.
Results:
Biofilm formation occurred on all implant materials, and neither roughness nor hydrophobicity had a decisive influence on biofilm formation. Zirconium-oxide attracted most biofilm. All implant materials were covered by human-gingival-fibroblasts for 80-90% of their surface areas. Human-gingival-fibroblasts lost the race-for-the-surface against all bacterial strains on nearly all implant materials, except on the smoothest titanium variants.
Significance:
Smooth titanium implant surfaces provide the best opportunities for a soft tissue seal to form on bacterially contaminated implant surfaces. This conclusion could only be reached in co-culture studies and coincides with the results from the few clinical studies carried out to this end.
More Related Videos
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025
Related Concept Videos
Biofilms
Development of the Oral Microbiota
Bacterial Signaling