Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
Comparison of voice relative fundamental frequency estimates derived from an accelerometer signal and low-pass
1Department of Biomedical Engineering, Boston University, Boston, Massachusetts 02215.
Abstract:
The relative fundamental frequency (RFF) surrounding the production of a voiceless consonant has previously been estimated using unprocessed and low-pass filtered microphone signals, but it can also be estimated using a neck-placed accelerometer signal that is less affected by vocal tract formants. Determining the effects of signal type on RFF will allow for comparisons across studies and aid in establishing a standard protocol with minimal within-speaker variability. Here RFF was estimated in 12 speakers with healthy voices using unprocessed microphone, low-pass filtered microphone, and unprocessed accelerometer signals. Unprocessed microphone and accelerometer signals were recorded simultaneously using a microphone and neck-placed accelerometer. The unprocessed microphone signal was filtered at 350 Hz to construct the low-pass filtered microphone signal. Analyses of variance showed that signal type and the interaction of vocal cycle × signal type had significant effects on both RFF means and standard deviations, but with small effect sizes. The overall RFF trend was preserved regardless of signal type and the intra-speaker variability of RFF was similar among the signal types. Thus, RFF can be estimated using either a microphone or an accelerometer signal in individuals with healthy voices. Future work extending these findings to individuals with disordered voices is warranted.
Related Concept Videos
Relative Motion Analysis - Acceleration
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Determination of Expected Frequency
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...