Delayed perforation of posterior pharyngeal wall caused by dislodged bioresorbable interbody cage. Case report
Krzysztof Zapałowicz1, Maciej Radek1, Maciej Wojdyn1
1Department of Neurosurgery and Peripheral Nerve Surgery, Medical University of Łódź, University Hospital WAM-CSW, Łódź, Poland.
Abstract:
A 48-year-old man was admitted for the management of congenital anomalies: Arnold-Chiari type I malformation combined with odontoid upward migration. He also had degenerative stenosis of the spinal canal by spurs at C2/C3 and C3/C4 levels. Osseous deformities caused ischaemic changes of the brainstem as well as spinal cord compression. Authors used the Biocage - interbody cage covered by bioresorbable layer to fill the surgically created gap after removal of the right part of C3 vertebral body. Twenty-seven months after implantation, the implant was extruded through posterior pharyngeal wall. Authors describe this unusual case and discuss possible causes of Biocage extrusion.