Related Experiment Video
Updated: Apr 29, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Biventricular Mechanical Circulatory Support Does Not Prevent Delayed Myocardial Ventricular Rupture following
Yazhini Ravi1, Emily P Sudhakar2, Pratima Nayak3
1Division of Cardiac Surgery, Department of Surgery, The Ohio State University, 420 W 12th Avenue, Columbus, OH 43210, USA.
Abstract:
Cardiogenic shock and myocardial rupture can complicate an acute myocardial infarction (AMI). A case is reported in which a 58-year-old male with an acute inferior myocardial infarction required placement of biventricular assist device for hemodynamic support eight days after the onset of his AMI; eleven days after his AMI, the patient developed abrupt onset of hemodynamic instability with massive bleeding from his chest tube due to delayed free wall myocardial rupture that was discovered when he was taking emergently to the operating room. Myocardial rupture in patients with a ventricular assist device should be considered in the differential diagnosis in the event of acute hemodynamic compromise. A high level of suspicion for such a complication should prompt aggressive and emergent actions including surgery. We present a case of delayed free wall myocardial rupture following an acute inferior wall myocardial infarction in a patient with biventricular mechanical circulatory support.