Flow-injection chemiluminescence method to detect a β2 adrenergic agonist

Guangbin Zhang1, Yuhai Tang, Jian Shang

  • 1School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, People's Republic of China; Institute of Analytical Science, Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, People's Republic of China.

Summary

A novel chemiluminescence method detects β2 adrenergic agonists using potassium ferricyanide-luminol. This sensitive assay accurately quantifies agonists in pharmaceuticals with high precision and repeatability.

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.5K
Labeling DNA Probes03:31

Labeling DNA Probes

DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
7.7K
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
1.3K