Related Experiment Video
Updated: Apr 29, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Advances in radiation biology: effect on nuclear medicine
Antone L Brooks1, Lawrence T Dauer2
1Washington State University, Kennewick, WA.
Abstract:
Over the past 15 years and more, extensive research has been conducted on the responses of biological systems to radiation delivered at a low dose or low dose rate. This research has demonstrated that the molecular-, cellular-, and tissue-level responses are different following low doses than those observed after a single short-term high-dose radiation exposure. Following low-dose exposure, 3 unique responses were observed, these included bystander effects, adaptive protective responses, and genomic instability. Research on the mechanisms of action for each of these observations demonstrates that the molecular and cellular processes activated by low doses of radiation are often related to protective responses, whereas high-dose responses are often associated with extensive damage such as cell killing, tissue disruption, and inflammatory diseases. Thus, the mechanisms of action are unique for low-dose radiation exposure. When the dose is delivered at a low dose rate, the responses typically differ at all levels of biological organization. These data suggest that there must be a dose rate effectiveness factor that is greater than 1 and that the risk following low-dose rate exposure is likely less than that for single short-term exposures. All these observations indicate that using the linear no-threshold model for radiation protection purposes is conservative. Low-dose research therefore supports the current standards and practices. When a nuclear medical procedure is justified, it should be carried out with optimization (lowest radiation dose commensurate with diagnostic or therapeutic outcome).
Related Concept Videos
Biological Effects of Radiation
Isotopes and Radioisotopes
An isotope containing...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...