Objective:
The effects of acute continuous positive airway pressure therapy on left ventricular diastolic function and functional capacity in patients with compensated systolic heart failure remain unclear.
Methods:
This randomized, double-blind, placebo-controlled clinical trial included 43 patients with heart failure and a left ventricular ejection fraction <0.50 who were in functional classes I-III according to the New York Heart Association criteria. Twenty-three patients were assigned to continuous positive airway pressure therapy (10 cmH2O), while 20 patients received placebo with null pressure for 30 minutes. All patients underwent a 6-minute walk test (6MWT) and Doppler echocardiography before and immediately after intervention. Clinicaltrials.gov: NCT01088854.
Results:
The groups had similar clinical and echocardiographic baseline variables. Variation in the diastolic function index (e') after intervention was associated with differences in the distance walked in both groups. However, in the continuous positive airway pressure group, this difference was greater (continuous positive airway pressure group: Δ6MWT = 9.44+16.05×Δe', p = 0.002; sham group: Δ6MWT = 7.49+5.38×Δe'; p = 0.015). There was a statistically significant interaction between e' index variation and continuous positive airway pressure for the improvement of functional capacity (p = 0.020).
Conclusions:
Continuous positive airway pressure does not acurately change the echocardiographic indexes of left ventricle systolic or diastolic function in patients with compensated systolic heart failure. However, 30-minute continuous positive airway pressure therapy appears to have an effect on left ventricular diastolic function by increasing functional capacity.
More Related Videos
Related Concept Videos
Heart Failure VI: Adjunct Therapies
Heart Failure V: Medical Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Heart Failure II: Pathophysiology
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...