Related Experiment Video
Updated: Apr 29, 2026

11:29
Novel 3D/VR Interactive Environment for MD Simulations, Visualization and Analysis
Published on: December 18, 2014
11.3K
Summary
No abstract available in PubMed .
Related Concept Videos
Power in a Three-Phase Circuit
750
Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
750
Sums of Power
196
In definite integration, Riemann sums approximate the area under a curve by dividing it into subintervals and summing the areas of rectangles. When these approximations follow predictable numerical patterns, such as arithmetic or polynomial sequences, sum formulas offer a more efficient and accurate way to compute the result. In particular, the sum of consecutive integers, squares, and cubes plays an essential role in simplifying these calculations, especially when dealing with uniform...
196
Three-Winding Transformers
1.0K
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
1.0K
The Maximum Power Transfer Theorem
1.4K
Consider a linear AC Thevenin equivalent circuit connected to a load impedance.
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
1.4K
The Power Superposition Principle
788
Consider a circuit with two sinusoidal voltage sources. Each one influences the circuit independently, and the superposition principle helps us understand the combined effect by adding up the responses from each source.
788
Generation of Three-Phase Voltage
1.1K
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
1.1K

