Related Experiment Video
Updated: Apr 29, 2026

Author Spotlight: Studying Brain Endothelial Barrier in Metastatic Cancer Using Impedance-Based Biosensors
Published on: September 22, 2023
Introducing a new method for evaluation of the interaction between an antigen and an antibody: single frequency
Burcu Özcan1, Burçak Demirbakan1, Gülden Yeşiller1
1Namık Kemal University, Faculty of Science and Arts, Chemistry Department, Biochemistry Division, Tekirdağ, Turkey.
This paper illustrates the application of an antibody, anti-parathyroid hormone (anti-PTH), as a bioreceptor in a biosensor system for the first time, and demonstrates how this biosensor can be used in parathyroid hormone (PTH) determination. The interaction between the biosensor and parathyroid hormone was firstly investigated by a novel electrochemical method, single frequency impedance analysis. The biosensor was based on the gold electrode modified by cysteine self-assembled monolayers. Anti-PTH was covalently immobilized onto cysteine layer by using an EDC/NHS couple. The immobilization of anti-PTH was monitored by cyclic voltammetry and electrochemical impedance spectroscopy techniques. The performance of the biosensor was evaluated in terms of linearity, sensitivity, repeatability and reproducibility, after a few important optimization studies were carried out. In particular, parathyroid hormone was detected within a linear range of 10-60 fg/mL. Kramers-Kronig transform was also performed on the impedance data. The specificity of the biosensor was also evaluated. The biosensor was validated by using a complementary reference technique. Lastly the developed biosensor was used to monitor PTH levels in artificial serum samples.
This paper illustrates the application of an antibody, anti-parathyroid hormone (anti-PTH), as a bioreceptor in a biosensor system for the first time, and demonstrates how this biosensor can be used in parathyroid hormone (PTH) determination. The interaction between the biosensor and parathyroid hormone was firstly investigated by a novel electrochemical method, single frequency impedance analysis. The biosensor was based on the gold electrode modified by cysteine self-assembled monolayers. Anti-PTH was covalently immobilized onto cysteine layer by using an EDC/NHS couple. The immobilization of anti-PTH was monitored by cyclic voltammetry and electrochemical impedance spectroscopy techniques. The performance of the biosensor was evaluated in terms of linearity, sensitivity, repeatability and reproducibility, after a few important optimization studies were carried out. In particular, parathyroid hormone was detected within a linear range of 10-60 fg/mL. Kramers-Kronig transform was also performed on the impedance data. The specificity of the biosensor was also evaluated. The biosensor was validated by using a complementary reference technique. Lastly the developed biosensor was used to monitor PTH levels in artificial serum samples.
More Related Videos
14:53A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
Published on: September 10, 2014
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
Related Concept Videos
Microbial Biosensors
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...