Related Experiment Video
Updated: Apr 29, 2026

Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
High-sensitivity analysis of anionic sulfonamides by capillary electrophoresis using a synergistic stacking approach
Ria Marni Tubaon1, Paul R Haddad1, Joselito P Quirino1
1Australian Centre for Research on Separation Science, School of Physical Sciences-Chemistry, University of Tasmania, Hobart, Tasmania 7001, Australia.
Abstract:
A synergistic stacking approach whereby field-enhanced sample injection and micelle-to-solvent stacking in capillary zone electrophoresis are combined has been developed and has been applied to the separation and quantification of anionic sulfonamides. Electrokinetic injection of the sample in a low conductivity alkaline diluent was performed for 90s at -15kV. Micelle-to-solvent stacking was then undertaken by hydrodynamic injection of micellar cetyltrimethylammonium bromide solution prior to the electrokinetic injection of sample that also contained 50% methanol. This combined stacking approach, when compared to a typical hydrostatic injection, provided improvements in peak height and corrected peak area in the range of 397-1024 and 758-1246, respectively. Limits of quantification in the range of 0.01-0.03μg/mL were obtained for sulfamerazine, sulfamethazine and sulfamethizole and were sufficient for the determination of these analytes in river water. The percentage recovery and accuracy values obtained for a fortified river water sample that had been subjected to sample preparation by evaporation and reconstitution with diluent were 74-135%. Intra-day and inter-day repeatabilities for migration time, peak height, and corrected peak area were in the range 0.5-5.0% (percentage relative standard deviation, n=8) and these relatively low values were attributed to the use of a stable capillary coating established by the successive multiple ionic-polymer layer technique.
More Related Videos
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Ion-Exchange Chromatography
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

