[A comparison of several convenient methods of estimating effective energy in X-ray computed tomography]
Hironori Kondo1, Kosuke Matsubara, Ayaka Hirosawa
1Department of Radiological Technology, School of Health Sciences, Kanazawa University.
Abstract:
The measurement of half-value layers (HVLs) and effective energy in X-ray computed tomography (CT) using conventional nonrotating methods is regarded as a highly challenging task, as it necessitates the use of a nonrotating X-ray tube and the assistance of service engineers. Several convenient methods have been proposed to circumvent this limitation; however, to the best of our knowledge, there are no reports that provide a comparative study on the accuracy of each method. This prompted us to compare the accuracy and practicality of each method. Effective energy was calculated using four methods: lead shielding, copper pipe, localization, and inner-metal center-air ratio (IMCAR). The accuracy of each method for the measurement of effective energy in X-ray CT was evaluated and compared with the conventional nonrotating method. The differences in the effective energy were 0.0 to 0.6 keV (0.0% to 1.1%) for lead shielding, -2.2 to -0.6 keV (1.4% to 4.3%) for copper pipe, 4.7 to 16.7 keV (9.9% to 31.4%) for localization, and -7.4 to -0.3 keV (0.6% to 17.5%) for the IMCAR method. The results indicate that the lead shielding method is the most accurate and practical method of estimating effective energy in X-ray CT.
More Related Videos
10:42In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
Published on: June 16, 2016
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography