Related Experiment Video
Updated: Apr 29, 2026

Combination of Microstereolithography and Electrospinning to Produce Membranes Equipped with Niches for Corneal Regeneration
Published on: September 12, 2014
Intrastromal corneal ring segments implantation in patients with keratoconus: 10-year follow-up
Purpose:
To evaluate the long-term safety and efficacy of Ferrara intrastromal corneal ring segments (ICRS) (Ferrara Ring; AJL, Boecillo, Spain) in patients with keratoconus.
Methods:
The chart records of 36 eyes of 30 patients with keratoconus implanted with ICRS, operated on between July 1996 and January 2002, were retrospectively reviewed. The following parameters were studied: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry (K), and central corneal thickness. The outcomes were evaluated at 5 and 10 years after ICRS implantation.
Results:
The mean UDVA (logMAR) improved from 1.01 ± 0.28 (20/200 Snellen) to 0.71 ± 0.38 (20/100 Snellen) at 5 years (P < .05) and 0.67 ± 0.25 (20/90 Snellen) at 10 years (P = .735). The mean CDVA (logMAR) improved from 0.45 ± 0.45 (20/55 Snellen) to 0.24 ± 0.19 (20/35 Snellen) at 5 years (P < .05) and 0.29 ± 0.09 (20/38 Snellen) at 10 years (P = .292). The mean maximum K value decreased from 54.99 ± 6.33 to 50.58 ± 5.11 D at 5 years (P < .05) and 50.65 ± 5.17 D at 10 years (P = .854). The mean minimum K value decreased from 48.85 ± 5.70 to 46.90 ± 5.08 D at 5 years (P < .05) and 47.12 ± 4.22 D at 10 years (P = .945). The central corneal thickness decreased from 457.42 ± 58.21 to 421.34 ± 74.12 μm at 5 years (P = .039) and 434.32 ± 77.65 μm at 10 years (P = .427).
Conclusions:
Intrastromal corneal ring segments can effectively improve UDVA and CDVA 10 years after implantation in patients with keratoconus.