Related Experiment Video
Updated: Apr 29, 2026

Mixed Reality Assisted Radical Endoscopic Thyroidectomy
Published on: January 31, 2025
Surgeon and staff radiation exposure during radioguided parathyroidectomy at a high-volume institution
Sarah C Oltmann1, Andrew V Brekke, Jose D Macatangay
1Section on Endocrine Surgery, Department of Surgery, University of Wisconsin, 600 Highland Ave., K4/739 Clinical Science Center, Madison, WI, 53792-7375, USA, oltmann@surgery.wisc.edu.
Introduction:
Radioguided parathyroidectomy (RGP) uses technetium-99 m sestamibi causing gamma ray emission during RGP to aid dissection and confirm parathyroid excision. Source (the patient) proximity and exposure duration determine degree of exposure. The purpose of this study was to quantify surgeon and staff radiation exposure during RGP.
Methods:
Surgeons and assistants wore radiation dosimeters during RGP procedures at a high-volume endocrine surgery practice. Area dosimeters measured personnel potential exposure. Data were prospectively collected. Provider exposures were corrected for both duration of exposure and case volume. Institutional safety requirements uses 100 mrem/year as an indicator for radiation safety training, 500 mrem/year for personal monitoring, and a maximum allowed exposure of 4,500 mrem/year.
Results:
A total of 120 RGP were performed over 6 months. Badges were worn in 82 cases (68 %). Three faculty and four assistants were included. Primary hyperparathyroidism was the diagnosis for 95 %. Median case volume per provider was 13 cases (range 6-45), with median exposure of 18 h (range 9-70). Mean provider deep dose exposure (DDE) was 22 ± 10 mrem. Corrected for exposure duration, mean DDE was 0.6 ± 0.2 mrem/h. Corrected for case volume, mean DDE was 0.8 ± 0.2 mrem/case. Anesthesia exposure was minimal, while mayo stand exposure was half to two thirds that of the surgeon and assistant. Based on institutional guidelines and above data, 125 RGP/year warrants safety training, 625 RGP/year warrants monitoring, whereas >5,600 RGP/year may result in maximum allowed radiation exposure to the surgeon.
Conclusions:
Surgeon and staff radiation exposure during RGP is minimal. However, high-volume centers warrant safety training.
More Related Videos
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
05:25Identification and Protection of the Recurrent Laryngeal Nerve during Transoral Robotic Thyroidectomy
Published on: October 24, 2025
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...