Related Experiment Video
Updated: Apr 28, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Is TOMPOOL (gated blood-pool SPECT processing software) accurate to diagnose right and left ventricular dysfunction
Laurent Dercle1, Thomas Giraudmaillet, Pierre Pascal
1Department of Nuclear Medicine, Toulouse University Hospital, 1, Avenue Jean Poulhès TSA 50032, 31059, Toulouse Cedex 9, France, laurent.dercle@gmail.com.
Background:
The assessment of right ventricular function is crucial for management of heart disease. TOMPOOL is a software that processes data acquired with Tomographic Equilibrium Radionuclide Ventriculography. In this report, TOMPOOL's diagnostic accuracy and inter-observer reproducibility were assessed in a cohort of patients with various etiologies of ventricular dysfunction.
Methods And Results:
End-diastolic volume (EDV), ejection fraction (EF), and cardiac output (CO) were calculated for the right ventricle (RV) and the left ventricle (LV) using TOMPOOL in 99 consecutive patients. Thirty-five patients underwent cardiac magnetic resonance imaging (CMR) considered as the reference-standard to measure EDV and EF; the Spearman's rho correlation coefficients were r = 0.73/0.80 and 0.67/0.73 for right/left EF and EDV, respectively. Twenty-one patients had thermodilution measurements of right CO (reference-standard), the correlation was r = 0.57. The best cut-off points (sensitivity/specificity) in order to diagnose a ventricular dysfunction or enlargement were 46% for RVEF (67%/89%), 62% for LVEF (100%/90%), 94 mL for RVEDV (77%/73%), and 84 mL for LVEDV (100%/91%). The areas under the ROC curve were, respectively, 0.79, 0.91, 0.83, and 0.99. Inter-observer reproducibility was r = 0.81/0.94, 0.77/0.90, and 0.78/0.75 for Right/Left EF, EDV, and CO, respectively.
Conclusion:
TOMPOOL is accurate: measurements of EDV, EF, and CO are reproducible and correlate with CMR and thermodilution. However, thresholds must be adjusted.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias