Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Factors of tidal volume variation during augmented spontaneous ventilation in patients on extracorporeal carbon
1Department of Anesthesia and Operative Intensive Care, Regensburg University Hospital, Regensburg, Germany - thomas.bein@klinik.uni-regensburg.de.
Background:
Extracorporeal carbon dioxide removal (ECCO2-R) allows lung protective ventilation using lower tidal volumes (VT) in patients with acute respiratory failure. The dynamics of spontaneous ventilation under ECCO2-R has not been described previously. This retrospective multivariable analysis examines VT patterns and investigates the factors that influence VT, in particular sweep gas flow and blood flow through the artificial membrane.
Methods:
We assessed VT, respiratory rate (RR), minute ventilation (MV), and levels of pressure support (0-24 cm H2O), sweep gas flow (0-14 L/min) and blood flow through the membrane (0.8-1.8 L/min) in 40 patients from the moment they were allowed to breathe spontaneously. Modest hypercapnia was accepted.
Results:
Patients tolerated moderate hypercapnia well. In a generalized linear model the increase in sweep gas flow (P<0.001), a low PaCO2 (P=0.029), and an increased breathing frequency (P<0.001) were associated with lower VT. Neither blood flow through the membrane (P=0.351) nor the level of pressure support (P=0.595) influenced VT size.
Conclusion:
Higher sweep gas flow is associated with low VT in patients on extracorporeal lung assist and augmented spontaneous ventilation. Such a technique can be used for prolonged lung protective ventilation even in the patient's recovery period.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Volumes and Capacities
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Acute Respiratory Failure-III
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...