Characterization and differentiation of body fluids, putrefaction fluid, and blood using Hounsfield unit in
Wolf-Dieter Zech1, Christian Jackowski, Yanik Buetikofer
1Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, 3012, Bern, Switzerland, Wolf-Dieter.Zech@irm.unibe.ch.
Abstract:
The purpose of the present study was to evaluate the ranges of Hounsfield unit (HU) found in body fluids, putrefaction fluids, and blood on postmortem CT and how these ranges are affected by postmortem interval, temperatures, and CT beam energy. Body fluids, putrefaction fluids, and blood from a total of 53 corpses were analyzed to determine the ranges of HU values from postmortem CT images that were taken prior to autopsy. The fluids measured in CT images were obtained at autopsy and examined in terms of macroscopic and microscopic appearances. Body fluids and blood were also collected in plastic bottles, which were subjected to CT scans at different beam energies (80-130 kV) and at various fluid temperatures (4 to 40 °C). At a postmortem interval of 1 to 4 days, the ranges of HU values of the serous fluids (13-38 HU) and the nonsedimented blood (40-88 HU) did not overlap. In the sedimented blood, the upper serum layer exhibited HU value ranges that overlapped with those of the serous fluids. The putrefaction fluids exhibited a range of HU values between 80 and -130 HU. Elevated HU values were observed in fluids with accretive cell impurities. HU values decreased slightly with increasing temperature and CT beam energy. We concluded that serous fluids and blood in fresh corpses can be characterized and differentiated from each other based on HU value ranges. In contrast, body fluids in decomposed corpses cannot be differentiated by their HU value ranges. Different beam energies and corpse temperatures had only minor influences on HU value ranges and therefore should not be obstacles to the differentiation and characterization of body fluids and blood.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...