Reliability and validity of sports accelerometers during static and dynamic testing
Stephen J Kelly1, Aron J Murphy, Mark L Watsford
1Faculty of Health, University of Technology Sydney, Sydney, NSW, Australia.
Summary
The SPI-ProX II accelerometers show excellent reliability for measuring acceleration but poor validity. Use with caution for high-frequency movements and conduct regular device assessments.
Area of Science:
- Biomechanics
- Sports Science
- Wearable Technology
Background:
- Accelerometers are widely used in sports science to measure movement and impact.
- The SPI-ProX II is a dual data logger frequently employed for such analyses.
- Assessing the accuracy and consistency of these devices is crucial for reliable data collection.
Purpose of the Study:
- To evaluate the validity and reliability of the SPI-ProX II dual data logger's accelerometry.
- To determine the accuracy and reproducibility of raw accelerometer data from the device.
Main Methods:
- Controlled laboratory experiments were conducted to assess the device.
- Intra- and interdevice reliability were tested for measuring peak gravitational accelerations (g).
- Static and dynamic validity were assessed against a criterion-referenced accelerometer across frequencies of 5 to 15 Hz.
Main Results:
- SPI-ProX II accelerometers demonstrated excellent intra- and interdevice reliability with low coefficients of variation.
- Validity testing revealed significant differences and poor accuracy, with high percentage differences (27.5-30.5%).
- Effect sizes indicated small to medium differences for reliability and large differences for validity.
Conclusions:
- The SPI-ProX II accelerometers exhibit high reliability but poor validity for measuring acceleration.
- Caution is advised when using these devices for absolute acceleration magnitude, especially in high-frequency movements.
- Regular device assessment and manufacturer guidelines for calibration are recommended to mitigate errors.